4.1Product Overview

4.1-1 Product Standard

GB/T12666.6           GB/T12706-2008        GB/T18380-2008

GB/T19216-2003        IEC331                BS6387-2013     

Q31/0116000686C003-2017()  BS841-2008


4.1-2 Definition

Flexible mineral insulation fire-proof cable BBTRZ is composed of copper strand conductor, inorganic mineral insulation, mineral compound filling, low smoke halogen-free outer sheath.


4.1-3 Structure

1.  stranded conductor

2.  Mineral insulation layer

3.  Mineral filling layer

4.  Low smoke halogen-free oversheath


Cable type composition:



      B   B   T  R  Z- 0.6/1KV -5X16


                                          Specification                                   

                                          Rated voltage    Light load 500V  Heavy load 600-1000v       

                                         Structural characteristic code   Light load Q    Heavy load Z   

                                         Hinged type

                                         Conductor material cod     Copper conductor

                                          Inorganic mineral belt wrapping     

                                         Distribution cable, power cable series          



See the cable notation examples in the following table

Names

Examples

BBTRZ flexible mineral insulated fire cable with rated voltage 0.6/1kv 5X16mm

BBTRZ-0.6/1-5X16

4.1-4 features

electrical specification

Rated operational voltage :Light load 450/750 v; Heavy load 0.6/1 kv

Rated current: single core 0-1800 A; multi-core 0-1362 A

Insulation resistance: insulation resistance 100MΩ·km; cable length <100 m, insulation resistance 1000

Power frequency withstand voltage :450/750 v cable and the 0.6/1 kv cable apply 2000 v and 3500 AC voltages respectively between phase and phase, phase and copper sheath for 15 min, without breakdown.

Operating temperature :-40-90; when short circuit (maximum duration not exceeding 5 s), maximum temperature of copper core cable conductor not exceeding 1000.

Rated power: Hz 49-61

Bending radius: cable bending radius 6-20 D


Fire resistance

According to the national experimental method of fire resistance test of wire and cable combustion: GB/T19216.21-2003 selection flame temperature 950 C~1000 C, recommended burning time of 180 min, BBTRZ cable line maintain integrity.

According to British BS6387-2013/BS8491-2008 standards,BBTRZ cables shall meet the following requirements:

C class of simple fire resistance :950 C±40 C 180min;

W class of fire and water resistance :650 C±40 C 15min;

Z class of fire resistance and mechanical vibration :950 C±40 C 15min


4.1 5 advantages

·High temperature resistant,

The integrity of the line can be maintained at the flame temperature of 950~1000℃ for 180 minutes.

·flexible and easy to bend

The conductor of the cable is made of mature multi-strand flexible copper wire stranded technology, and the outer sheath is made of new halogen-free special material extruded and wrapped, which has the characteristics of softness, and will not be cracked and damp.

·Large Current-Carrying Capacity

Compared with cables of the same section, BBTRZ flexible mineral insulated cable can not only transmit higher current, but also can withstand larger overload.

·large section with multiple cores

Because of the use of advanced equipment and technology, the multi-core cable can reach 5X300mm, the construction is more convenient, economic, and consistent with the ordinary cable laying and installation.

·the continuous length is long

he cable length can be customized according to the requirements of the buyer. The cable is wound on the cable disk in a coil, without adding cable connector in the middle, eliminating the potential safety hazard

4.2 Design Selection

Detailed data refer to section 1.2

4.3 Technical parameters

One core cable

Nominal cross section area/mm2

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

1X16

1.1

-

10.5

344

95

1X25

1.1

-

12.1

458.2

125

1X35

1.2

-

13.1

564.6

155

1X50

1.3

-

15.4

725.3

190

1X70

1.3

-

17.8

948

240

1X95

1.3

-

19.6

1213.2

295

1X120

1.3

-

20.6

1472.4

345

1X150

1.5

-

23.2

1770.1

395

1X185

1.5

-

24.5

2159.9

460

1X240

1.5

-

27.1

2717.8

545

1X300

1.8

-

30.2

3339.6

630

1X400

1.8

-

32.7

4198

730

1X500

2.0

-

37.2

5334.6

845

1X630

2.0

-

40.5

6720.2

970

Notethe temperature of environment is 30while that of the metal sheath is 70.

4 core cable

Nominal cross section area/mm2

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

4X2.5

0.45

0.45

10.7

376.8

32

4X4

0.45

0.45

11.3

476.7

40

4X6

0.45

0.45

13

578.3

52

4X10

0.55

0.55

16.5

787.9

69

4X16

0.55

0.55

19

960.8

88

4X25

0.55

0.55

22.1

1398

115

4X35

0.6

0.6

25.6

1834.8

145

4X50

0.65

0.65

29.5

2367.8

180

4X70

0.65

0.65

32.1

3356.8

225

4X95

0.65

0.65

36.3

4445.9

275

4X120

0.65

0.65

39

5468.8

320

4X150

0.75

0.75

41.4

6835.8

360

4X185

0.75

0.75

44.4

8390.6

415

4X240

0.75

0.75

51.2

10080.8

490

Notethe temperature of environment is 30while that of the metal sheath is 70.

3+1 core cable

Nominal cross section area/mm2

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

3X16+1X10

0.55

0.55

18.8

1002

88

3X25+1X16

0.55

0.55

21.8

1399.7

115

3X35+1X16

0.6

0.6

24.6

1678.8

145

3X50+1X25

0.65

0.65

26.8

2178.9

180

3X70+1X35

0.65

0.65

31.7

2956.8

225

3X95+1X50

0.65

0.65

35.3

4076.9

275

3X120+1X70

0.65

0.65

39.5

5107.9

320

3X150+1X70

0.75

0.75

41.6

6076.9

360

3X185+1X95

0.75

0.75

44.7

7545.9

415

3X240+1X120

0.75

0.75

48.3

9406.8

490

3X300+1X150

0.9

0.9

53.7

12075.9

565

Notethe temperature of environment is 30while that of the metal sheath is 70.

5 core cable

Nominal cross section area/mm22

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

5X2.5

0.45

0.45

13.2

450.7

32

5X4

0.45

0.45

14.3

578.3

40

5X6

0.45

0.45

16.5

713.9

52

5X10

0.55

0.55

17.9

917.9

69

5X16

0.55

0.55

22.6

1217.8

88

5X25

0.55

0.55

27.2

1857.8

115

5X35

0.60

0.60

31.3

2337.8

145

5X50

0.65

0.65

32.6

3100.7

180

Notethe temperature of environment is 30while that of the metal sheath is 70.

4+1 core cable

Nominal cross section area/mm22

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

4X16+1X10

0.55

0.55

21.4

1145.8

88

4X25+1X16

0.55

0.55

23.7

1698.9

115

4X35+1X16

0.6

0.6

27.4

2178.9

145

4X50+1X25

0.65

0.65

29.4

2839

180

4X70+1X35

0.65

0.65

33

3869.7

225

4X95+1X50

0.65

0.65

39.6

5378.9

275

4X120+1X70

0.65

0.65

40.9

6684.9

320

4X150+1X70

0.75

0.75

43.5

7957.4

360

4X185+1X95

0.75

0.75

45.7

9867.3

415

4X240+1X120

0.75

0.75

51.3

11898.8

490

4X300+1X150

0.9

0.9

56.2

15585.4

565

Notethe temperature of environment is 30while that of the metal sheath is 70.

3+2 core cable

Nominal cross section area/mm2

Nominal thickness of the core insulated/mm

Nominal thickness with insulation/mm

Approximate outer diameter of cable/mm

KG/mm

Cable carrying capacity in open air   A

3X16+2X10

0.55

0.55

21.2

1079.8

88

3X25+2X16

0.55

0.55

23.2

1567.9

115

3X35+2X16

0.6

0.6

25.5

1960.8

145

3X50+2X25

0.65

0.65

28.1

2572.9

180

3X70+2X35

0.65

0.65

32.1

3586.9

225

3X95+2X50

0.65

0.65

38.9

4804.4

275

3X120+2X70

0.65

0.65

40.6

6051.8

320

3X150+2X70

0.75

0.75

42.7

7055.2

360

3X185+2X95

0.75

0.75

45.2

8945.8

415

3X240+2X120

0.75

0.75

50.6

10088.4

490

3X300+2X150

0.9

0.9

56.1

14674.9

565

Notethe temperature of environment is 30while that of the metal sheath is 70.